10kA JVL16-100 Popular 2p automatic Residual Current Circuit Breaker
10kA JVL16-100 Popular 2p automatic Residual Current Circuit Breaker
10kA JVL16-100 Popular 2p automatic Residual Current Circuit Breaker
10kA JVL16-100 Popular 2p automatic Residual Current Circuit Breaker
10kA JVL16-100 Popular 2p automatic Residual Current Circuit Breaker
10kA JVL16-100 Popular 2p automatic Residual Current Circuit Breaker

Item specifics

Mode
electro-magnetic type
Residual current characteristics
A,AC,G,S
Pole No
2, 4
Rated making and breaking capacity
10InA
Rated current(A)
63, 80, 100
Rated voltage
AC 230/400
Rated frequency
50/60Hz
Terminal Connection Height
19mm
Electro-mechanical endurance
4000 cycles
Protection class
IP20

Review

Description

Technical Data

● Mode: electro-magnetic type

● Residual current characteristics: A, AC,G,S

● Pole No.: 2, 4

   ● Rated making and breaking capacity:            500A(ln=25A,40A) or 630A(ln=63A)

● Rated current(A): 25, 40, 63

● Rated voltage: AC 230(240)/400(415)

● Rated frequency: 50/60Hz

● Rated residual operating current IAn(A):0.03, 0.1, 0.3, 0.5

●Rated residual non operating current lAno: 0.5IAn

● Rated conditional short-circuit current Inc: 10kA

● Rated conditional residual short-circuit Current I Ac: 10kA
● Residual tripping current range: 0_5IAnH An

● Terminal Connection Height: 19mm

● Electro-mechanical endurance: 4000 cycles

● Connection capacity: Rigid conductor 25mm²

● Connection terminal:Screw terminal

● Pillar terminal with clamp

● Fastening torque: 2.0Nm

● Installation: On symmetrical DIN rail 35mm Panel mounting 

● Protection class:IP20

 Construction and Feature


Elegant appearance; cover and handle in arc shape make comfortable operation. Contact position indicating window

Transparent cover designed to carry label.

In case of overload to protected circuit, RCBO handle trips and stays at central position, which enables a quick solution to the faulty line. The handle cannot stay in such position when operated manually.

RCBO handle can be locked either at “ON” position or at“OFF” position to prevent unwanted operation of the product. 

Provides protection against earth fault/leakage current, short-circuit and overload

High short-circuit capacity

Provides complementary protection against direct contact by human body.

Effectively protects electric equipment against insulating failure

Contact position indication

Provides protection against over-voltage

Overall & Installation Dimensions
Wiring Diagram